ModbusClientRTU API elements
You will have to have the following include line in your code to make the ModbusClientRTU
API available:
#include "ModbusClientRTU.h"
Important when using HardwareSerial
Modbus RTU has been modified to accept any Stream
-based object for reading and writing serial data. Note that this requires a version of the arduino-esp32
core of 2.0.x and higher. Due to the timing requirements of Modbus, a HardwareSerial
connection needs to be configured properly to work with eModbus.
-
Call the
RTUutils::prepareHardwareSerial()
method for your serial interface The UART buffer needs to be large enough to hold a complete message - else timing errors will happen.
A reasonable size for Modbus RTU is 260, this is set by the method for both Rx/Tx buffers.
The call must be made before theHardwareSerial::begin()
call to be effective.
The call is like (Serial1
taken as an example)
RTUutils.prepareHardwareSerial(Serial1);
-
Now call your
Serial
’sbegin()
.
Also note that the ModbusClientRTU::begin()
call needs to be given the serial interface as first parameter. Additionally any Stream
-type interface needs the baud rate as a second parameter as well. A HardwareSerial
is requested internally for the baud rate. This is used to calculate the interval times between messages on the RTU bus. Incorrect values may lead to messages being missed.
ModbusClientRTU()
,
ModbusClientRTU(int8_t rtsPin)
and
ModbusClientRTU(int8_t rtsPin, uint16_t queueLimit)
These are the constructor variants for an instance of the ModbusClientRTU
type. The optional parameters are:
rtsPin
: a GPIO number, where the DE/RE wire of the attached RS485 adapter is connected - should your adapter need one.queueLimit
: this specifies the number of requests that may be placed on the worker task’s queue. If the queue has reached this limit, the nextaddRequest
call will return aREQUEST_QUEUE_FULL
error. The default value built in is 100.
Note
While the queue holds pointers to the requests only, the requests need memory as well. If you choose a queueLimit
too large, you may encounter “out of memory” conditions!
ModbusClientRTU(RTScallback func)
and
ModbusClientRTU(RTScallback func, uint16_t queueLimit)
These are the alternative constructor variants for an instance of the ModbusClientRTU
type. The parameters are:
func
: this must be a user-defined callback function of typevoid func(bool level);
. This function is called every time the RS485 adaptor’s “DE/RE” line has to be toggled. The required logic level is given as the only parameter to the function. This is relevant if your adaptor will need a special treatment to set these levels (being behind a port extender or such).queueLimit
: this specifies the number of requests that may be placed on the worker task’s queue. If the queue has reached this limit, the nextaddRequest
call will return aREQUEST_QUEUE_FULL
error. The default value built in is 100.
void begin(Stream& s, uint32_t baudrate)
,
void begin(Stream& s, uint32_t baudrate, int coreID)
and
void begin(Stream& s, uint32_t baudrate, int coreID, uint32_t userInterval)
or
void begin(HardwareSerial& s)
,
void begin(HardwareSerial& s, int coreID)
and
void begin(HardwareSerial& s, int coreID, uint32_t userInterval)
This is the most important call to get a ModbusClient instance to work. It will open the request queue and start the background worker task to process the queued requests.
You need to give the baud rate of the used Stream
as first parameter to enable eModbus to correctly calculate the interval between messages! For HardwareSerial
interfaces the baud rate is inquired internally.
The optional parameter coreID
may be used to have that background task run on the named core for multi-core MCUs. Default for coreID
is -1, in which case the system will pick the core for its own rules.
The last, again optional, parameter can be userInterval
. There are devices in the wild that can not handle the (short) Modbus standard quiet times (“intervals”) but will need a longer time between messages to recover. The user defined interval is given in micro seconds, but may not be shorter than the standard defines for the given baud rate.
Note
The worker task is running forever or until the ModbusClient instance is killed that started it. The destructor will take care of all requests still on the queue and remove those, then will stop the running worker task.
void setTimeout(uint32_t TOV)
This call lets you define the time for stating a response timeout. TOV
is defined in milliseconds. When the worker task is waiting for a response from a server, and the specified number of milliseconds has passed without data arriving, it will return a TIMEOUT
error response.
Note
This timeout is blocking the worker task. No other requests will be made while waiting for a response.
uint16_t RTUutils::calcCRC16(uint8_t *data, uint16_t len)
and
uint16_t RTUutils::calcCRC16(ModbusMessage msg)
This is a convenient method to calculate a CRC16 value for a given block of bytes. *data
points to this block, len
gives the number of bytes to consider. The call will return the 16-bit CRC16 value.
bool RTUutils::validCRC(const uint8_t *data, uint16_t len)
and
bool RTUutils::validCRC(ModbusMessage msg)
If you got a buffer holding a Modbus message including a CRC, validCRC()
will tell you if it is correct - by calculating the CRC16 again and comparing it to the last two bytes of the message buffer.
bool RTUutils::validCRC(const uint8_t *data, uint16_t len, uint16_t CRC)
and
bool RTUutils::validCRC(ModbusMessage msg, uint16_t CRC)
validCRC()
has a second variant, where you can provide a pre-calculated (or otherwise obtained) CRC16 to be compared to that of the given message buffer.
void RTUutils::addCRC(ModbusMessage& raw)
If you have a ModbusMessage
(see above), you can calculate a valid CRC16 and have it pushed o its end with addCRC()
.
void useModbusASCII()
and void useModbusASCII(unsigned long timeout)
If you are going to use the Modbus ASCII protocol, you may switch the RTU client to ASCII mode by these calls. In ASCII mode all messages are encoded as a sequence of human-readable ASCII characters. The first character always is a colon :
, the last two characters of a message always are \r\n
(CRLF), as the Modbus specs require it. All message bytes are sent as their hexadecimal representations, followed by a LRC checksum.
Note: everything else is identical to Modbus RTU, so your code will remain the same with the exception of this very call.
The optional timeout
parameter allows to alter the standard 1s timeout the specs describe. This may help speeding up communications if all your servers are supporting the shorter timings.
void useModbusRTU()
This call will switch off a previously set ASCII mode and return to RTU mode.
Note: this will NOT reinstate the previously given RTU timeout! You may to have to set it again with setTimeout(unsigned long timeout)
instead.
bool isModbusASCII()
This call is to report back if the ASCII mode currently is active (true
) or RTU mode is selected (false
).
void skipLeading0x00(bool onOff = true);
Some RTU bus setups have unresolvable issues with sporadic ‘ghost’ 0x00 bytes created within the electronics that have no logical representation at all. The skipLeading0x00()
call allows to have these bytes droped internally, if these are received in front of a proper message.
Note: this is a work-around only to cure a symptom and does not fix the issue. It always pays to try to fix the root cause!
Error addBroadcastMessage(const uint8_t *data, uint8_t len)
This call will add a broadcast request to the queue. data
may contain whatever you will find appropriate. The only thing the library will add is a leading 0x00 byte to signal a broadcast request and the CRC.